Common name and synonyms.
Roof mate butter grade flashing.
Sds us 8.
1 to 5 aqua ammonia 10 30 1336 21 6.
On horizontal metal roof seams the butter grade should be applied in a 3 to 4 inch strip in 2 coats to a total thickness of 60 to 80 wet mils centered over the seam.
Its thick buttery consistency allows it to be easily worked into vertical seams on metal roofs gaps in flashings and around protrusions and into heavily alligatored areas in weathered built up roofing.
It utilizes the latest advances in acrylic technology is used to repair and reinforce penetrations and seams.
The fabric is very pliable and is designed to conform to irregular and dissimilar surfaces.
Use with roof mate fabric for extra strength.
Roof mate fabric offers a combination of high strength properties and good elongation for excellent thermal stress resistance.
United coatings roof mate butter grade flashing provides increased tensile strength and elongation on problem roof areas united coatings roof mate butter grade flashing is a water based high solids acrylic sealant utilizing the latest advances in acrylic technology.
United coatings roof mate butter grade flashing version.
Roof mate butter grade flashing has high solids and has a thick buttery consistency which allows it to be easily worked into vertical seams on metal roofs into gaps in flashings around protrusions and into.
Tough polyester fabric surface.
1 to 5 titanium dioxide.
Roof mate flashing is a water based acrylic flashing and is part of the roof mate coating system.
0 1 to 1 carbamic acid.
It is used in with roof mate butter grade flashing to repair or reinforce penetrations and seams.
United coatings roof mate butter grade flashing is a water based acrylic flashing and is part of the roof mate coating system.
11 8 2017 sds 3013.
Roof mate butter grade flashing is a water based high solids elastomeric sealant utilizing the latest advances in advanced acrylic technology.
Its thick buttery consistency allows it to be easily worked into vertical seams on metal roofs into gaps in flashings around protrusions and into heavily alligatored areas in weathered asphaltic roofing.
All seams must first be checked to assure that there is no more than 1 4 deflection when pressure is applied below the seam.
It utilizes the latest advances in acrylic technology is used to repair and reinforce penetrations and seams.